The firmware was changed to insure that error log entries related to ambient temperature problems (error codes such as 11007201, 11007203, and 11007205, for example) are sent up to the operating Fixed a problem on i5 and p5 systems that causes a continuous stream of phantom interrupts on partitions with shared processors. In SF235_206 and later service packs, this fix is CONCURRENT. All Rights Reserved. navigate here

You can think of the first part as the test code and the second part as the fault code. This feature comes in a variety of part numbers but the CCIN should always be 185D. The failure is due to a timing condition in the SF230_120 and SF230_126 firmware (look for an error log with the SRC B181873C). All rights reserved. http://www.ibm.com/support/knowledgecenter/POWER5/ipha6_p5/b1xxa.htm

Hmc Error Codes

This affects the following systems: i5: 9405-520 and 9406-520 with processor feature code 8325, 8327 or 8330 p5: 9115-505, 9110-51A, 9111-285, 9131-52A, and 9133-551 System firmware changes that affect model 570 Please try the request again. Enhancements to the "Restore to factory default" option, CoD options, time-of-day menu, and firmware update policy menu on the ASMI menus.

This page is rather extensive and will be updated on a regular basis. A problem was fixed that caused some error log entries not to be seen on the HMC. resource_type=sys,type_model_serial_num=9119-595*512884E,sp=primary, ipaddr=192.168.255.250,state=Connected resource_type=sys,type_model_serial_num=9119-595*512884E,sp=backup, ipaddr=192.168.252.255,state=No Connection resource_type=frame,type_model_serial_num=9458-100*918000X,side=a, ipaddr=192.168.253.253, state=No Connection resource_type=frame,type_model_serial_num=9458-100*918000X,side=b, ipaddr=192.168.254.251, state=Connected Note: Only 590, 595 and 575 systems will display multiple components. DEFERRED Fixed a problem that causes the default boot list and the stored boot list to be swapped in the system management services (SMS) firmware when booting an AIX or Linux

SF225_080_080 Impact: New Severity: New Added support for 9118-575, 9110-510, and 9123-710. B150f22a A new function was added to system firmware to allow power code downloads to towers to be enabled and disabled. A problem was fixed that was causing dynamic logical partitioning operations in a Linux environment to hang intermittently. SF222 SF222_081_081 Impact: Function Severity: Hiper Fixed a problem that caused FSCSI errors to show up erroneously in the AIX error log when an I/O adapter failed.

In a system with a redundant service processor, a problem was fixed that was causing an invalid error code (B181E436) to be generated during a concurrent firmware update. Therefore, I hope to provide this to all those other technicians out there who get the opportunity to work on one of these. Product Engineering does NOT recommend upgrading 9119 systems without using this ECA. If you are currently affected by this problem, a server IPL must be performed to reactivate the low-level HSL Opticonnect connection between the servers.

B150f22a

Firmware File Information and Update Description Filename Size Checksum 01SF240_233_201.rpm 15219922 30964 SF240 SF240_233_201 Impact: Function Severity: Hiper System firmware changes that affect all p5 and i5 systems: A problem was http://unix.derkeiler.com/Newsgroups/comp.unix.aix/2006-03/msg00026.html All other system types will only return a single line for each managed system. Hmc Error Codes If two power supplies are installed, the system may fail to power on if one power supply fails in the 9110-510, 9111-520, 9113-550, 9117-570, 9123-xxx, 9124-xxx, 9405-520, 9406-520, 9406-550, 9406-570 systems. The terminating SRC can be found in the ASMI error logs.

DEFERRED and HIPER: Additional hardware initialization settings were changed to prevent system hangs with B7xx406E reference code. check over here Example: Currently installed service pack is SF230_126_120, new service pack is SF230_143_120. Two related error codes logged are: 1. 508FF44B CEC Hardware Subsystem Unrecoverable Error SRC = B150F22A 2. 508FF402 CEC Hardware Subsystem Unrecoverable Error SRC = B150F22A Result Priority: Mandatory, replace all Third Party Maintenance24 X 7 AccessBlended OEM Support OptionsCentrics Support Services FAQGlobal ServicesSLA OptionsSecure Stocking LocationsIMACIT InstallationsData Center PlanningIT Asset Discovery and ManagementOur ProcessPersonalized ConsultationsOnsite Audit and Health CheckSimple ContractsParts Sparing

On model 590 and 595 systems, fixed a problem that was causing DDR II memory cards in slots C10 and C12 to fail the memory test during a slow-mode boot. A problem was fixed that was causing SRC B1xxE500 (with SRC word 8 equal to DD02) when processor runtime diagnostics were called during a dump. You are likely to encounter this error when connecting and powering on a 16-way, two-drawer IBM 9116-561 server. http://sisei.net/error-code/oven-error-code-f1.html In firmware level SF230_150, there was a deferred fix that affects all p5 and i5 systems: partition using a DLPAR (dynamic LPAR) operation is reduced.

A problem was fixed that caused the system to fail to boot if the white power button was pressed within 10 seconds after reaching standby, but before C1802000 was posted on For deferred fixes within a service pack, only the fixes in the service pack which cannot be concurrently activated are deferred. Forum Operations by The UNIX and Linux Forums Log In E-mail or User ID Password Keep me signed in Recover Password Create an Account Blogs Discussions CHOOSE A TOPIC Business

System firmware changes that affect model 570 systems with more than one processor drawer: On model 570 systems with more than one processor drawer, a problem was fixed that was preventing

Although the error clearly points at the service processor, the description "not enough functional nodes" indicates that the flex cables could be a potential cause, given that both drawers appear to Verify power is applied to the dispenser. (Check out our Hyosung ATMs for sale & our Triton ATMs for sale) Error 385 (Check out our Hyosung ATMs for sale & Call home should be enabled again at the end of the firmware installation. Click on the link "Processing unit Deconfiguration" to bring up the page that shows the processing units in the system and if any is presently deconfigured.

The 00 means that no fault was found. 201 would mean a memory error. 202 would mean memory address error; lines 00-15. P550 Error Code BI50B10C Waweru asked Jan 22, 2013 | Replies (4) I have p550 server which when I restarted it gives me an error code BI50B10C and cannot come up,what A problem was fixed that caused the system to fail to boot if the white power button was pressed within 10 seconds after reaching standby, but before C1802000 was posted on weblink If this problem is the cause for your failure, it is recommended you update to SF230_145 or a later SF230 service pack prior to performing the upgrade to this SF240 service

If this problem is encountered, the system must be rebooted for the adapter to be correctly configured after the repair. Adds support for F/C 7894, 8GB (4x2GB) feature (2GB DDR2 DIMMs, CCIN 30F3) on machine type 9117-570. You can verify your network connections by running the following HMC command from an rsh window: lssysconn -r all Below is a sample output of the lssysconn command for a single SF230_145_120 Impact: Serviceability Severity: Special Attention Fixed a problem on i5 systems with 5074 I/O towers that causes a partition to hang with SRC B6000255 when an I/O adapter in the

Fixed a highly intermittent problem that causes the service processor to perform a dump when an SRC is displayed on the control panel. Ensure that there are no outstanding serviceable events showing on the Service Focal Point before starting the firmware installation. The codes that I am presenting here are from documents I have read through, found on the web, found in old books, documents and technical papers. A feature to retry boot from a hard disk after an initial failure due to firmware timing, instead of immediate failure. (This type of failure is typically seen on boot disks

DEFERRED On model SR110000 systems only, fixed a problem that was causing the I/O in the CEC not to show up after an IPL. Added support for the installation of two copies of the AIX operating system on one hard file. If you know of any error codes that I am displaying incorrectly or that aren't here. Maintenance Login 1-877-531-7466 Request a Quote MenuIT Support ServicesWhy Centrics Support?The Centrics Support PhilosophyCentrics Support Services AdvantageOEM vs.