Home > Error Code > Panasonic H 11 Error

Panasonic H 11 Error

Contents

Remove dirt and reconnect sensors to solve the issue. Panasonic Air Conditioners 1 Answer The timer light on my Panasonic CW-1006FU Air... Keep up the good work. We will work on this on Monday and get back to you. Expert: Appliance Expert 64 replied3 years ago. check over here

Panasonic Error Code Diagnosis display = H00 Abnormality / Protection control = No abnormality detected Abnormality Judgement = Emergency operation = Norma... Check for correct wiring and adjust the voltage to the recommended value. Instead of sweltering outside of the station while waiting for trains to pull in, commuters for the first time can relax inside the station, in air-conditioned comfort.air conditioninair conditionerac air conditioningfurnacehvac how can i solve? http://www.refrigeration-engineer.com/forums/showthread.php?16264-Panasonic-wall-split-inverter-problem

Panasonic Aircon Error Code

Browse Categories Answer Questions Panasonic CW-XC243HU Air Conditioner Panasonic Air Conditioner Air Conditioners All Unanswered Join Sign In Ask a Question × HomeForumAir ConditionersPanasonicCW-XC243HU Air ConditionerPanasonic... H30/31 (faulty outdoor discharge sensors) – wipe off any dirt from the contact surface and reconnect the sensor. Slim P Series A air conditioner fault codesMitsubishi MR. H27 (faulty outdoor air sensor) – this is another common problem caused by faulty or dirty contact surfaces as well as disconnected sensors.

H28 (faulty outdoor pipe sensor) – this is yet another problem caused by disconnections or dirty and faulty contact surfaces. Share on Facebook Share on Twitter Share on Google+ Share on Pinterest Share by Email × Question about Panasonic CW-XC243HU Air Conditioner Open Question Panasonic cs-ps12jkm-5 inverter error code h11 I Wipe of any dirt from the contact surface and reconnect the sensor to restore functionality. Panasonic Air Conditioner Error Codes Download F90 (PPC failure) – these are caused by faulty inverters or compressors.

If not, somethings wrong with the wiring or ourdoor unit. F-96. If No Voltageis present either the cable or Indoor PCB must be faulty. click to read more Results 1 to 4 of 4 Thread: Panasonic wall split inverter problem Thread Tools Show Printable Version Subscribe to this Thread… Display Linear Mode Switch to Hybrid Mode Switch to Threaded

This can be determined by checking the voltageoutput on the Comms terminal of the Indoor unit, with the Comms wire disconnected. Panasonic Air Conditioner Troubleshooting Also displays error code H 11...Help...Please...its hot in here H-11Indoor / outdoor abnormal communication. Blog Archive ► 2014 (6) ► August (2) ► May (1) ► April (3) ► 2012 (9) ► July (1) ► June (3) ► January (5) ► 2011 (18) ► December Wipe off any dirt from the contacts and reconnect sensor to solve the issue.

Panasonic Inverter Air Conditioner Error Codes

Please read as C5.Fault Code 05 and 53 (CH05 is displayed at indoor unit, 53 is displayed at outdoor unit)This fault code indicates a communication error between the indoor and outdoor https://www.manualslib.com/manual/116990/Panasonic-Cs-He9dke.html?page=71 If there is a communication error fault CH05 will appear within 5mins of powering up the system.Testing• Check Outdoor and Indoor Power Supply Voltages ( 230V ±10% ) and correct as Panasonic Aircon Error Code H12 (ID/OD compatibility problem) – this is usually caused by over-indexed or under-indexed multi system. Error H11 Panasonic Inverter I replaced new power pcb but problem still exist.

Feel free to continue this thread if you need anymore assistance. check my blog Raise the gas level to correct and try to change the transistor module. Replace outdoor PCBReconnect terminal 3 wire and measure Vdc between terminal 2 & 3 from the outdoor unit. Have a manual for Panasonic CW-XC243HU Air Conditioner? Panasonic Inverter Air Conditioner Error Code F95

Plus fault codes from the indoor unit make it easier to look up. Resolving the problem requires general cleaning maintenance and increasing gas levels. Can somebody expert in inverter aircon help me. http://sisei.net/error-code/panasonic-error-f-91.html The system returned: (22) Invalid argument The remote host or network may be down.

This is a sign of a bad board. Panasonic F90 Error Code Routine maintenance can resolve issues of operated float switches and H21 functions. Regular cleaning and maintenance will resolve the problem unless it is complex which may require comprehensive troubleshooting.

If your remote functions fail to induce the expected effect, you may need to troubleshoot a number of issues to return the syncing correspondence.

I find them very professional in their work. Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Your positive rating is my goal. Ask Your Own Appliance Question Customer: replied3 years ago. Panasonic Air Conditioner Error Code H00 F97 (high compressor temperature and discharge) – this issue occurs due to faulty compressors or low gas charge.

Open ventilation spaces and replace faulty or dirty filters with clean functional ones. You may have to register before you can post: click the register link above to proceed. Refrigeration-Engineer.com, the administrators and Moderators of this site are not responsible for content posted here. How To Solve Common Panasonic Aircon Codes? http://sisei.net/error-code/panasonic-error-u01.html Loading...Oops :Please try again.

OK. Ensure the wires and pipes are not crossed to enable seamless flow of electricity and air. Register Help Remember Me? Your cache administrator is webmaster.

if the compressor is running, check the amps and refrig pressures. If it is H11, than the indoor unit has not had a reply from the outdoor units for 60 seconds, communications are performed over interconnects 2 and 3. Add × Loading... Include an image.

Replace the PCB to correct or seek professional troubleshooting to determine why the motor is locked. My error is number 15, I have to contact the repairer to see what it means. Please try the request again. The Panasonic aircon enjoys remarkable reception and positive reviews mainly for its efficiency in promoting indoor comfort.

Dear Expert,Thank you very much for the answer, i have now decided to change the outdoor PCB, please could you help me regarding where i can get the PCB for the Using other similar Panasonic... Reason: Thread moved to correct section 01-12-2008,04:21 AM #2 paul_h View Profile View Forum Posts View Blog Entries View Articles VIP Poster I am starting to push the Mods: of Can somebody expert in inverter aircon help me.

F96 (overheating IPM or compressor) – can be caused by dirty heat exchangers as well as excess or low gas charge. Correct the fault by establishing the correct index. We offer 24-hour service, 365 days of the year with fully-trained,licensed and nsured technicians for all residential and commercial applications.air conditioninair conditionerac air conditioningfurnacehvac Unknown on December 23, 2015 at 1:33 H16 (transformer faults) – this can be caused by very low gas, faulty PCB or failing Power Transistor Module.

H41 (abnormal wiring and piping) – this is caused when piping or wiring cross each other on a twin system. Jun 03, 2008 | Air Conditioners 1 Answer Panasonic split system air con cs/cu-e24gkr check the indoor unit sirkit board,there is problem.