Home > Water Heater > Paloma Tankless Water Heater Error Code 12

Paloma Tankless Water Heater Error Code 12

Contents

Provide adequate air supply, and proper venting, and do not expose to flammable vapors. Bleed all air from the gas line.Make sure that Paloma unit is properly grounded.Gas supply system has to be properly sized.Check is there an obstruction in the venting system. Check outlet with basic circuit analyzer Unit will not power ON/ pdf When power is applied to tankless, then Green indicator light will show, and continue to show as long as Read product manual. http://sisei.net/water-heater/paloma-tankless-water-heater-error-code-c4-76.html

I was not expecting the whole board to be coated in a glue, however! Bosch posted a bulletin how to remove and clean the burner. Bath Controllers, as their name implies, should be placed in your two main bathrooms. Posted on Oct 29, 2009 Helpful 23 Not Helpful 4 Comments Flag 2 more comments TERRY LEE Oct 17, 2010 poluma sent me a new gas valve not fixed then they

Paloma Tankless Water Heater Parts

Oh that's right, Rheem is one of those people with last name Corporation, so they allowed to lie up folks to get money. American Heat ADK-2... Check for other filters on household water line. Check for pipe dope inside water flow control turbine.

Buy: Tankless water heaters at Amazon Tent City USA tankless water heater/ off grid Larger logo Gas odor If you smell gas, leave building immediately and call gas company from outside Do not install propane tankless in basement. I had the same problem with my Paloma a year and a half after installation...contacted Rheem customer service (800-432-8373) and they recommened a local installer in my area. Paloma Water Heater Manual Even with 3/4” gas piping, you may not be getting enough gas to the Paloma if the run is too long or it is competing with too many other gas appliances.

What is the reason . Sparky Channel 21,849 views 10:05 Descaling a Noritz tankless water heater - Duration: 21:52. Expand Popular Questions 8 Answers Error code 13 (air flow) tankless H20 Rheem Rheem RTG-74PVN-2 Natural Gas... 4 Answers Combustion shutoff system tripped how do you reset Rheem Water Heaters 5 Check gas solenoid valves for open or short circuits.

Expert 117 Answers Re: Paloma tankless, gas, water heater, error code C7 76 It's the remote controller remove it(the remote controller wires) and see if it kicks on and works fine, Paloma Tankless Water Heater Error Code C4 12 Generated Sat, 22 Oct 2016 09:55:40 GMT by s_ac5 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.9/ Connection Governor: An expert whose answer got voted for 20 times. The burner assembly has these 3 pins that look like number 7's these are covered with build up and gas can't flow right.

Paloma Tankless Water Heater Tech Support

Thanks Mat. plumber will charge you for service. Paloma Tankless Water Heater Parts Ensure maximum vertical vent length does not exceed allowable limits. Paloma Tankless Water Heater Error Codes C4 Follow newest idea on twitter Waterheatertimer.org is a self-help site Compare 16 electric and 2 gas water heater timers Try a water heater timer free Figure Volts Amps Watts for water

The Rheem product manual for tankless electric might no show how to wire the product. have a peek at these guys Tankless operation overview/ pdf Maintain your water heater/ pdf Maintain water heater 2012/ pdf Removal and cleaning Rheem Tankless burner Paloma use and care Buy flushing system $199 or Buy whole While the code may indicate that the unit isn't receiving enough "fuel", I wonder if this could also mean oxygen, as air is required to allow for combustion. and imagine telling the jury how you believed that spending lota money to buy a computer-chip water heater that requireslarger gas line and larger vent pipe was magically going to supply Paloma Tankless Water Heater Manual

Draining it will remove less than a quart of water, but not doing so can cause serious damage to the heat exchanger if it freezes. One possible cause; Crossover caused by bad single handle faucet cartridge drawing cold water into line causing shut down of tankless burner?Copy following links for resources:http://waterheatertimer.org/Crossover.htmlhttp://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.htmlAdd a comment as needed.Genehh Aug Check for restrictions in air flow around unit and vent termination. http://sisei.net/water-heater/paloma-tankless-water-heater-error-code-13.html Replace PCB. 72 Flame Sensing Device Fault Ensure flame rod is touching flame when unit fires.

well that was before 2015 heh heh Buy whole new tank-type electric for $250 And save money to buy toxic Chinese dog food No Service Manuals? Paloma Tankless Water Heater Error Code P1 Generated Sat, 22 Oct 2016 09:55:40 GMT by s_ac5 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection Pay for service.

Best wishes for all folks.

Check gas pressure. View Most Popular Paloma PTG-74PVN / RTG-74PVN Natural Gas Indoor Water Heaters Related Question My Paloma pg-711fr is turning itself off and error 12 comes up Water Heaters Open Questions: 0 Can anyone help? Rheem Tankless Water Heater Error Codes C7 And there are no service manuals.

you have not altered your home in any way that changes any of the clearances). Please enter a valid email address. You may NOT copy or distribute the content that appears on this site without written permission from Fixya Ltd. © 2005-2015, Fixya, Ltd. this content All-Star: An expert that got 10 achievements.

You can't post answers that contain an email address. Ask a professional to check your gas supply. Turn off, or remove circulation pumps (unit is not designed for continuous operation with circulation systems). 05 Imperfect Combustion Alarm Clean air inlet filter. Open windows.

I use my Paloma at my vacation home. Find the most common problems and troubleshooting codes on Paloma water heaters.Is your Paloma unit not producing enough hot water or water is cold? Factor in maintenance, possibility of expensive repair, no service manuals, no local service techs, cost of parts, cost of replacement, limited warranty, no warranty if you install yourself .... Brian's How 2 20,094 views 55:09 TankLess Water Heaters (Learn from my mistake) - Duration: 3:26.

Call plumber to check vent. Thanks Rheem Paloma tankless computer? TP can release water when TP valve is defective, and when debris is caught under lever. Lift and release the lever to make certain that it operates freely.

Following manual applies to older tankless. Without remote: default 120 degrees F Minimum temperature setting 85 degrees F Tankless must be connected to 120V outlet with correct polarity. wait ... The C4-C8 portion of the error code, is where the unit stops the ignition process...burner fails to light, or gives you intermittent hot water.

It looks like a metal pin with a couple of wires coming out of it this was also very dirty.