Home > Water Heater > Paloma Tankless Water Heater Error Codes C2 11

Paloma Tankless Water Heater Error Codes C2 11

Contents

then every 1/2'' up mark it as 1''. section with a 1 1/4" pipe then, via bell housing reducer to, 3/4" nipple to the flex pipe. (ah, I don't know, but I heard somewhere that sometimes an 'expansion chamber' You basically take apart 1/2 the unit, be carfull not to lose any screws and label all the little brackets that come off. Sediment trap is usually a 3" long piece of pipe pointed downwards with a cap on the end. http://sisei.net/water-heater/paloma-tankless-water-heater-error-codes.html

Bleed all air from gas lines. Rheem Paloma Tankless Water Heaters PTG-74PVN Tankless RTG-74PVN Open Questions: 0 Answers Getting Code C4 35 water goes hot then luke warm was getting code C7 35 water was going from Remember the tankless is already consuming as much gas as possible. If the tank is improperly vented, the error code will display.

Paloma Tankless Water Heater Error Code 13

curious to hear what you find. Rheem tankless default factory temperature is set at 100 degrees, without remote control. Click "Add" to insert your video. dalevan2000 123.100 προβολές 9:15 Tankless Direct Vent intake and exhaust (common errors and misconceptions) - Διάρκεια: 10:17.

you have not altered your home in any way that changes any of the clearances). Maybe error 12 can be related to this issue... Posted on Jan 06, 2010 Helpful 2 Not Helpful Comment Flag You can't post conmments that contain an email address. × Comment Anonymously Video Images joedirty Level 2: An expert who Paloma Tankless Water Heater Error Code P1 Do not install propane tankless in basement.

This makes for both comfortable and safe showering. You like the claim of 'endless hot water?' And the claim that tankless save money? Otherwise, you can only clean the three in the front of the burner assembly. http://www.fixya.com/support/t3044278-tankless_water_heater_paloma_c2_11_error Ensure proper venting material was installed.

Corporal: An expert that has over 10 points. Paloma Water Heater Error Code C4 i can take it apart in 20 min. Check for restrictions in air flow around unit and vent termination. Because different activities need different temperatures, we recommend that, if possible, you place the Main Controller inside your home in a location easily accessed from your kitchen.

Paloma Water Heater Tech Support

Why do you need a service manual? ... more info here Email me with any Q's at [email protected] Good Luck All that you need is a long phillips screw drive and a drill because its about 25 screws The burner assembly has Paloma Tankless Water Heater Error Code 13 Install tempering tank. Paloma Gas Heater Error Code 11 Just like sjackel, I found myself cleaning it every 3-6 months.

replace with an electric or other not so high tech device ... have a peek at these guys It was intalled as our house was on the market and sold weeks later. And this webpage was available BEFORE you bought the thing.... After it started failing again they sent out a new circuit board but that didn't solve any problems. Paloma Tankless Water Heater Error Codes C4

Pipe cannot be threaded at terminationor capped-off or obstructed. On commercial water heater, lower setpoint temperature below 180 F at high altitude. 16 Over Temperature Warning Check for clogged heat exchanger. I did clean the burner and it solved itNow 8 month later it happened again. check over here http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html#no-error http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html#temperature Gene Feb 14, 2014 | Rheem Paloma Tankless Water Heaters... 1 Answer Thermostat is set @120 then drops to 65 and starts flashing.

Stop the condensation from going down into the unit and most all the problem will go away. Richmond Tankless Water Heater Code 11 Expert 248 Answers Re: Tankless water heater (Paloma) Has C2 11 error Overheat stat or fan best of luck Posted on Oct 16, 2009 Helpful 1 Not Helpful Comment Flag You If you cannot reach your gas supplier, call the fire department.

And there are no service manuals.

Ensure flame rod wire is connected. Replace sensor. 35 Improper Thermistor Connections Check that all thermistors are connected to proper connections on PCB. 51 Gas Inlet Solenoid Fault Check gas inlet solenoid valve wiring harness for loose Maximum temperature for Rheem tankless is tepid 120 degrees, using the remote. Paloma Ptg-74pvn-2 Manual The discoloration from being in the flame does not go away but the crud sure does.

Seems to be... When the unit is warm, the mixture is too rich. Top Rheem Water Heaters Experts Mike Butler Level 3 Expert 6674 Answers Barrett Palumbo Level 2 Expert 1772 Answers Mike Cairns Level 3 Expert 3053 Answers Are you a Rheem Water this content Ensure condensation collar was installed properly.